3. Determining HAP Emissions From the Affected Source
The source must include in their low-risk demonstration
every process unit within the PCWP affected source that emits
one or more of the following HAP:
acetaldehyde
acrolein
arsenic
benzene
beryllium
cadmium
chromium
formaldehyde
lead
MDI
manganese
nickel
phenol
The source must conduct emissions testing using the methods
specified in appendix B in the PCWP MACT rule. For reconstituted
wood product presses or reconstituted wood product board
coolers, the source must determine the capture efficiency
of the capture device. If the source uses a control device
for purposes of demonstrating that their affected source
is part of the low-risk subcategory, then they must collect
monitoring data and establish operating limits for the control
system using the same methods specified in the PCWP MACT
rule (subpart DDDD).